ID : 10340
I/O Options Available to Set by WINCAPSIII
This section describes for the following each item.
- Digital Input Terminal
- Digital Output Terminal
- Digital Input/Output Terminal
- Field Network Slave Terminal
- Serial Communication Terminal
- Junction
- Others
Digital Input Terminal
When you click a model type, an individual instruction manual will be displayed.
| Model type | Name |
|---|---|
| EL1098 | Digital input terminal NPN, 8ch, 10us, IP20 |
| EL1889 | Digital input terminal NPN, 16ch, 3ms, IP20 |
| EL1018 | Digital input terminal PNP, 8ch, 10us, IP20 |
| EL1809 | Digital input terminal PNP, 16ch, 3ms, IP20 |
- These are available to equip to the robot controller.
- Signals of the digital input terminal should be allocated to the range of port numbers from 3072 to 3455 (total 384 points). As a result of connecting multiple digital input terminals to the robot controller, if the total number exceeds 384 points, the available number to use in the robot program in actual is up to 384 points.
Digital Output Terminal
When you click a model type, an individual instruction manual will be displayed.
| Model type | Name |
|---|---|
| EL2088 | Digital output terminal NPN, 8ch, 0.5A, IP20 |
| EL2889 | Digital output terminal NPN, 16ch, 0.5A, IP20 |
| EL2008 | Digital output terminal PNP, 8ch, 0.5A, IP20 |
| EL2809 | Digital output terminal PNP, 16ch, 0.5A, IP20 |
- These are available to equip to the robot controller.
- Signals of the digital output terminal should be allocated to the range of port numbers from 3456 to 3839 (total 384 points). As a result of connecting multiple digital output terminals to the robot controller, if the total number exceeds 384 points, the available number to use in the robot program in actual is up to 384 points.
Digital Input/Output Terminal
When you click a model type, an individual instruction manual will be displayed.
| Model type | Name |
|---|---|
| EP2339-0021 | Digital input/output terminal PNP, 16ch, 3ms, IP67 |
- This is not available to equip to the robot controller.
- Signals of the digital input/output terminal should be allocated to the range of port numbers from 3840 to 4095 (total 256 points). As a result of connecting multiple digital input/output terminals to the robot controller, if the total number exceeds 256 points, the available number to use in the robot program in actual is up to 256 points.
Field Network Slave Terminal
When you click a model type, an individual instruction manual will be displayed.
| Model type | Name |
|---|---|
| EL6631-0010 | PROFINET RT device terminal |
| EL6652-0010 | EtherNet/IP slave terminal |
| EL6711-0010 | CC-Link slave terminal |
| EL6731-0010 | PROFIBUS slave terminal |
| EL6752-0010 | DeviceNet slave terminal |
| EL6695 | EtherCAT bridge terminal |
- These are available to equip to the robot controller.
- Field network slave terminal can be used only one of the above terminals. Multiple field network slave terminals cannot be used.
Serial Communication Terminal
When you click a model type, an individual instruction manual will be displayed.
| Model type | Name |
|---|---|
| EL6002 | RS232C 2ch terminal |
| EL6022 | RS422/RS485 2ch terminal |
- These are available to equip to the robot controller.
- Serial communication terminal cannot use the multiple same models. For example, one EL6002 and one EL6022 can be used for each, but two EL6002 cannot be used.
Junction
When you click a model type, an individual instruction manual will be displayed.
| Model type | Name |
|---|---|
| CU1123 | EtherCAT junction 3port |
| CU1124 | EtherCAT junction 4port |
| CU1128 | EtherCAT junction 8port |
- These are not available to equip to the robot controller.
- There is the restriction of devices that can be used depending on the junction connection position. For details, refer to "Restriction when Using a Junction".
Others
When you click a model type, an individual instruction manual will be displayed.
| Model type | Name |
|---|---|
| EK1100 | EtherCAT coupler terminal |
This is available to equip to the robot controller.