ID : 1010
Status Area
This section describes the usage of the status area (16 bits, output) and of status area odd parity (output).
Function
Signals output the result of I/O command processing to the external device.
Usage
Signals are used to execute an I/O command and obtain the result of the PLC.
ON Conditions
- When processing of the I/O given is completed, the status corresponding to the command will be set.
- "ON" represents the bit value = 1. "OFF" represents the bit value = 0.
- If a command outputs status area, it outputs 1 or 0 to parity bit so that the total of 1s existing in the status area and status area parity will be odd.
OFF Conditions
- Signal will be turned OFF when the strobe signal is turned OFF.
- If the strobe signal is turned OFF, before command processing is completed, the status signal will be output and then turned OFF within 100 ms.
ID : 1010