MC_ReadDIBit

To read an I/O input signal of robot controller. (Bit)

Graphic expression FB No. FB category
FB2136 Non motion

Input parameter

Parameter name Data type Valid range Default Omission (*)
AxesGroup Integer 1 or larger 1 No
Robot number
Specify an element number for the variable "Robots[n]" (variable in the data block "DB_DENSO_ROBOTS (DB2990)") mapped to the controlled robot (robot controller).
If a specified value exceeds the valid range, the CPU (PLC) stops.

The maximum valid range value is the maximum element number of the variable "Robots[n]". The default maximum element number is 10 but can be increased or decreased by the user.

Execute Boolean
  • True : Start
  • False : -
False No
Execution start
When the parameter is changed from False to True, this FB is executed.
IoType Integer
  • 0 : Hand I/O
  • 1 : Mini I/O
0

Yes

Type of DIO
Specify the type of DIO.
IoBitNo Integer
  • Hand I/O : 0 to 7
  • Mini I/O : 0 to 15
0 Yes
Bit number of I/O
Specify an I/O bit number. 
For details, refer to Function description.

(*) : For some parameters, entries can be omitted.

  • Yes : Entry can be omitted.
  • No : Entry required always.

Output parameter

Parameter name Data type / Description
Done Boolean
Execution completion confirmation
True : This FB execution is completed.
False : This FB execution is not completed.
Busy Boolean
Processing status of this FB
True : Being executed.
False : Not being executed.
Error Boolean
Error presence
True : This FB ended abnormally.
False : This FB ended successfully.
ErrorID Word
Error location
2800 (hexadecimal) : The error occurred in the PLC program.
2801 (hexadecimal) : The error occurred in the robot controller.
ErrorIDEx DWord
Error Code
This is a number to identify the error description.
For details, refer to "Error code list".
Value Boolean
Input value
True : 1
False : 0

Function description

This function block reads an I/O input signal of robot controller.

The following tables show the correspondence between robot controller port number and bit number.

  • Hand I/O
    IoBitNo Robot controller port number Robot controller I/O name
    0 48 Hand input
    1 49 Hand input
    2 50 Hand input
    3 51 Hand input
    4 52 Hand input
    5 53 Hand input
    6 54 Hand input

    7

    55 Hand input
  • Mini I/O
    IoBitNo Robot controller port number Robot controller I/O name
    0 0 User input
    1 1 User input
    2 2 User input
    3 3 User input
    4 4 User input
    5 5 User input
    6 6 User input

    7

    7 User input
    8 8 User input
    9 9 User input
    10 10 User input
    11 11 User input
    12 12 User input
    13 13 User input
    14 14 User input
    15 15 User input