<< Prev        Next >>

ID : 5204

Wiring of Primary Power Source

Precautions for Wiring of Primary Power Source

Observe the following precautions when wiring the primary power source of the robot controller.

About Primary Power Source

  • Use the correct power source (200 VAC or 100 VAC) for the controller specification.
  • Be careful not to confuse AC 100V with AC 200V (or AC 230V), and also three-phase with single-phase.
  • Connect the robot power cable to a power source separate from the welder power source.
  • To cut off the controller power supply, use customer-prepared-breaker.

Protective Grounding

Before connecting the power cable, make sure to connect 2.5mm2 or higher level of wire (yellow / green) to the earth terminal (protective grounding) of the front metal panel. When disconnecting the bonding wire connected to the earth terminal (protective grounding) of the front metal panel, make sure to disconnect the power cable beforehand.

Additional Precautions

  • Do not bundle the teach pendant cable, I/O cables or motor & encoder cable together with high power lines such as power cables and peripheral device cables, or route the motor cables near high power devices (motor, welder, parts feeder, etc.).
  • Do not route any additional cables or air tubes of end-effectors through the robot unit. Doing so will result in broken cables or tubes.
  • When you connect the controller's functional grounding, ground a wire with 1.25mm2 or larger.

Robot Controller Power Supply Specifications

The following list shows the power supply specification of controllers.

Use the correct power supply for specifications below.

Be careful not to confuse AC 100V with AC 200V, and also three-phase with single-phase.

Do not use voltage greater than 240V.

Three-phase, 200V AC

Item Specifications
Power voltage Three-phase, 200 VAC -15% to 240 VAC +10%, 47 to 63 Hz
Power supply capacity VM : 3.3kVA *1
VS-6556/6577 : 1.8kVA *1
VS-068/087 : 2.78kVA *1
VS-050/060 : 1.15kVA *1
VP : 1.0kVA *1
HM : 2.45kVA *1
HS : 1.8kVA *1
HSR : 1.8kVA *2
XR : 1.85kVA *1
Max. rush current when the power is turned ON 40 A (for 1/50 or 1/60 second)
Pin assignment on power connector

A : 200 VAC, phase R (red)

B : 200 VAC, phase S (white)

C : 200 VAC, phase T (black)

D : Protective ground (green / yellow)

Models except UL-Listed ones
UL-Listed model

*1 : Except for RC8A Safety I/O-less specification

*2 : Available with RC8A only

Single-phase, 230V AC

Item Specifications
Power voltage Single-phase, 230 VAC -10% to 240 VAC +10%, 47 to 63 Hz
Power supply capacity VS-6556/6577 : 1.8kVA *1
VS-068/087 : 2.78kVA *1
VS-050/060 : 1.15kVA *1
HM : 2.45kVA *1
HS : 1.8kVA *1
HSR : 1.8kVA *2
XR : 1.85kVA *1
Max. rush current when the power is turned ON 40 A (for 1/50 or 1/60 second)
Pin assignment on power connector

A : 230 VAC, phase R (red)

B : 230 VAC, phase S (white)

D : Protective ground (protective earth) (green / yellow)

Models except UL-Listed ones
UL-Listed model

*1 : Except for RC8A Safety I/O-less specification

*2 : Available with RC8A only

Single-phase, 100V AC

Item Specifications
Power voltage

Single-phase, AC100V-5%~AC110V+10%, 47 to 63

* Extended-joint specification is not compatible with 100V input.

Power supply capacity VP : 1.0kVA *1
Max. rush current when the power is turned ON 40 A (for 1/50 or 1/60 second)
Pin assignment on power connector

A : 100 VAC, phase R (red)

B : 100 VAC, phase S (white)

D : Protective ground (protective earth) (green / yellow)

*1 : Except for RC8A Safety I/O-less specification

ID : 5204