<< Prev        Next >>

ID : 5421

Solenoid Valve Specifications (VS-6556/6577 series)

Solenoid valve specifications of VS-6556/6577 series are common.

Item Specifications

Valve

Switching system 2-position double
Applicable fluid Air
Operating system Pilot type
Effective cross section (Cv value)

P→A·B: 1.116mm²(0.062)

A·B→R: 1.188mm²(0.066)

Lubrication Oilless
Operating pressure range 0.1 to 0.7 MPa (Note 1)
Response time 15 ms or less (at 0.5 MPa)
Maximum operating frequency 10 Hz
Ambient temperature -5 to 50°C (No dew condensation allowed. When dry air is used)

Solenoid

Operating voltage 24 V ±10%
Power consumption (current) 0.5 W (21 mA)
Surge voltage protection circuit Zener diode

Note 1:The air source connected to the robot unit must be used within the operating pressure range from 0.10 to 0.39 MPa (refer to "Robot Specifications ").

Pneumatic Circuit

When both solenoids A and B are deenergized, the valve holds its position.

A, B Air outlet to tools
P Air inlet from AIR1
EA, EB

To exhaust ports

For clean room type, these are connected to “VALVE-OUT” (AIR2) of a connector panel.

The Valve Exhaust Port

Do not cover the valve exhaust port behind the second arm.

ID : 5421