<< Prev        Next >>

ID : 58

5th-axis CALSET position (VS-050/060)

Determine the CALSET position of the 5th axis of the VS-050/060 using the 4th-axis CALSET bolt.

Set the 4th-axis CALSET bolt in the position shown below and then gently press the 5th axis against the negative-direction end by hand. (The 4th-axis CALSET bolt is stored in the encoder backup battery box. Refer to "Encoder Backup Battery Box".)

ID : 58

<< Prev        Next >>