ID : 2439
Installation Environment of the Robot Unit
Before installing the robot unit and robot controller, confirm that the operating environment is in conformity with each item of "SAFETY PRECAUTIONS, Installation Precautions". Also, take proper measures to protect the components from vibration.
In an inappropriate environment, the robot will not operate to its full capacity or performance, components may not last long, and unexpected failure may result.
Vibration
Do not install the robot in an environment where it will be exposed to excessive vibration or impact.
To prevent damage of the installed robot from excessive impact or vibration during transportation, place the robot so that all axes contact with mechanical stoppers. Be sure to take measures to protect each axis such as wrapping up axis with cushions.
When the robot unit with the power off has undergone an excessive vibration during transportation, the ERROR 0x8320411* (Encoder reference position error) may occur.
If the ERROR 0x8320411* occurs when the robot power is first turned ON after purchase, refer to the "ERROR CODE TABLES" or contact the DENSO service representative.
Connecting the Robot Unit and Robot Controller
Before delivery, the robot unit and the robot controller are adjusted to each other as a set. When two or more robots are to be used, use the robots and robot controllers that have been adjusted to each other as a set.
A robot set, which consists of a robot unit and a robot controller, have a common same serial number.
Installation Environment of the Robot Unit
The table below lists the installation requirements for the robot unit.
- Do not electric-weld the equipment including the robot. A large current may flow through the motor encoder or robot controller resulting in a failure. If electric welding is required, remove the robot unit and the robot controller from the equipment beforehand.
- In operation, do not apply any direct jet flow into the bellows.
Item | Environments and Conditions |
---|---|
Installation type | Floor-mount or overhead-mount *(Do not install a robot horizontally.) |
Ambient temperature | During operation: 0 to 40℃ During storage and transportation: -10 to 60℃ |
Humidity | During operation: 20 to 90% RH (No dew condensation allowed.) During storage and transportation: 40 to 75% RH (No dew condensation allowed.) |
Vibration | During operation: 4.9 m/s2 (0.5G) or less During storage and transportation: 29.4 m/s2 (3G) or less |
Altitude | During operation: 1,000 m or less |
Safe installation environment | Refer to the SAFETY PRECAUTIONS, "Insuring the Proper Installation Environment". |
Working space, etc. | • Sufficient service space must be available for inspection and disassembly. • Keep wiring space behind the robot, and fasten the wiring to the mounting face or beam so that the weight of the cables will not be directly applied to the connectors. Wiring space for motor and encoder cable must be at least
|
Grounding conditions | See "Grounding the Robot Unit". |
ID : 2439