<< Prev        Next >>

ID : 3191

MC_ReadVecVar

To call an V-type variable stored in the robot controller.

Graphic expression FB No. FB category
FB2112 Non motion

Input parameter

Parameter name Data type Valid range Default Omission (*)
AxesGroup Integer 1 or larger 1 No
Robot number
Specify an element number for the variable "Robots[n]" (variable in the data block "DB_DENSO_ROBOTS (DB2990)") mapped to the controlled robot (robot controller).
If a specified value exceeds the valid range, the CPU (PLC) stops.

The maximum valid range value is the maximum element number of the variable "Robots[n]". The default maximum element number is 10 but can be increased or decreased by the user.

Execute Boolean
  • True : Start
  • False : -
False No
Execution start
When the parameter is changed from False to True, this FB is executed.
VectorVarNo Integer 0 or larger 0 Yes
Number of V-type variable
Specify the number to call.

(*) : For some parameters, entries can be omitted.

  • Yes : Entry can be omitted.
  • No : Entry required always.

Output parameter

Parameter name Data type / Description
Done Boolean
Execution completion confirmation
True : This FB execution is completed.
False : This FB execution is not completed.
Busy Boolean
Processing status of this FB
True : Being executed.
False : Not being executed.
Error Boolean
Error presence
True : This FB ended abnormally.
False : This FB ended successfully.
ErrorID Word
Error location
2800 (hexadecimal) : The error occurred in the PLC program.
2801 (hexadecimal) : The error occurred in the robot controller.
ErrorIDEx DWord
Error Code
This is a number to identify the error description.
For details, refer to "Error code list".
VectorVarData eRC_Vector
V-type variable data

Function description

-

Attention

-

ID : 3191

<< Prev        Next >>