ID : 5561

Field Bus Parameter Setting

This section describes the way of node address setting and communication speed setting of DeviceNet master board.

1 

From the tree in the left side of the display, click [Configuration] - [Bus Parameters].

 

For [MAC ID] and [Baud Rate] on the right side of the window, select following items.

1 MAC ID

Select node address of DeviceNet Master board from the range of 0 to 63

2 Baud Rate Select the communication speed of DeviceNet from 125Kbps, 250Kbps and 500Kbps

 

 
2

With the teach pendant, specify error-related settings.

From the top screen—[F4 I/O]—[F6 Aux.]-[F4 Field Bus parameter]

DeviceNet Master ErrDisplay

This parameter allows you to choose whether the network error will display in "every time" or is display at the "first time" only.

This parameter is set to "0" (EveryTime) by default for safe operation of the facilities. Every time an I/O operation is carried out, an error will display if any.

To check program operations using dummy I/Os for setting up facilities where no connection to the network has been established, set this parameter to "1" (First Time). Doing so will not display errors once detected, allowing you to check program operations.

  First Time

EveryTime

(Default Setting)
DeviceNet ErrDisplay 1

0

 

 
After completion of setting-up, be sure to set this parameter back to "0."

DeviceNet Insensitive time to network error [ms]

f the Communication check of DeviceNet communication starts too early after the Robot controller startup, an error [8350200B Prepare for field network communication] might be displayed immediately after booting.
To prevent such error, adjust "EtherCAT Insensitive time to network error" of Fieldbus parameter longer.

  Available range Default Setting
DeviceNet Master Insensitive time to network error [ms] 0~65535

20000

 

 

 

This completes the bus parameter setting.