ID : 1416
Command Processing Completed (output)
Function
This signal outputs to the external device that I/O command processing is completed.
Terminal number
#52 on Mini I/O connector.
Usage
The signal is used to confirm that I/O command processing is complete, or as a timing signal for obtaining the result of I/O command processing.
ON conditions
- The signal will be turned ON upon completion of processing the I/O command given.
- If an error occurs as a result of executing an I/O command, the Robot Error signal and the Command Processing Completed signal will be turned simultaneously ON.
OFF conditions
- The signal will be turned OFF when the Strobe Signal is turned OFF.
- If the Strobe Signal is turned OFF before command processing is completed, the Command Processing Completed signal will be output and then turned OFF within 100 ms.
ID : 1416