ID : 1400
Robot Error (output)
Function
This signal tells the external device that a servo error, program error, or any other serious error has occurred in the robot.
Terminal number
#47 on Mini I/O connector
Usage
- This signal is used to light the robot error indicator lamp on the external operating panel.
- If this signal is turned ON, perform the error recovery with the PLC.
ON conditions
When a level 1 error or higher one occurs.
OFF conditions
As shown below, the signal will be turned OFF under the following conditions.
- When a Clear Robot Error (001) signal is inputted and the existing error is cleared.
- When the existing error is cleared by operating the OK or Cancel key on the teach pendant or the mini-pendant.
Timing chart
|
ID : 1400