Strobe Signal (Input)
Function
This signal informs the Robot Controller that the command area, data areas 1 and 2, and the command and data area odd parity bit have been set. Additionally it directs the start of command processing.
Perform command input with a strobe signal after the system output signal ROBOT INITIALIZATION COMPLETE is output.
Input Conditions and Operation
- By turning ON this input in automatic or external mode, the Robot Controller reads the command area, data areas 1 and 2, and the command and data area odd parity bit starts processing.
- Retain the status until a command processing complete signal is output and the necessary status data is read. If the strobe signal is turned OFF before a command processing complete signal is output, the status area will not be output.
- By turning OFF this input after the status is read, the command processing complete output, the status area and the status parity will be turned OFF.