ID : 3076

States of System Output Signals in the RC3 Compatible Mode

When the cooperative control function is used, some of system output signals on the master controller output the logical AND or OR of both the master and slave controller states.

In the RC3 compatible allocation mode, the states of system output signals on the master controller are as follows.

Signal name State to be output
RC3 compatible mode signals Robot Running Master
Robot Error OR
Auto Mode Master
External mode
Program Start Reset
Robot Power ON Completed AND
Servo ON OR
CAL Completed Always ON
Teaching ON Master
1 Cycle End
Battery Warning OR
Robot warning
Continue start Permission Master
Error number OR
SS Mode Always OFF
CPU Normal Each state
Safety-circuit signals Pendant Emergency Stop (output)
Deadman SW (Enable SW output)

STO Monitor (output)

(RC8A only)

Auto Mode Mutual Monitoring (output)

(RC8A only)

Contactor Contact Monitor (output)

(RC8 only)

Signals that can be used by the parameter settings Running Stop Processing OR
Robot controller startup completed
Robot Running (Position designation)
Robot Running (Encoder)
Change Battery
Motor OFF indicator
32bit Error Code Output Master

 

 

  • The following information is shown in "State to be output" in the table above.
    State description Indication
    Logical AND of the master and slave controller state AND
    Logical OR of the master and slave controller state OR
    Master controller state Master
    Always ON regardless of the robot controller state Always ON
    Always OFF regardless of the robot controller state Always OFF
    The states of the master and slave controllers are output from their respective robot controllers. Each state
  • CPU Normal and safety-circuit signals are allocated to Mini I/O even if an I/O extension board is installed.
  • For signals that can be used by the parameter settings, refer to "Status Output with User Output Ports".