<< Prev        Next >>

ID : 1756

Recover CALSET Data

Operation path : [F2 Arm] - [F12 Maintenance] - [F7 CALSET]] - [F2 Recover CALSET data]

This CALSET is done when encoder system down occurs.

Bring the joint, where the system failure occurred, to the near mechanical end, and execute [Recover CALSET data] to recover encoder information similar to the original condition.

Press [F2 Recover CALSET data] to display the following [Recover CALSET data] window.

Ver.2.8.* or Higher

If the controller version is 2.8.* or later, the CALSET position is editable in the Recover CALSET data window.

The initial values for the CALSET position at the power-on are equal to the RANG values.

If the CALSET data recovery is done after the power-on, the CALSET position that has been set at the CALSET data recovery operation will be displayed.

To individually select ON/OFF for each joint, directly touch ON/OFF characters of each joint to set.

Pressing [OK] on the window will execute CALSET by using the CALSET position displayed on the right side of the window.

Also, by pressing [F1 Read CALSET Pos], CALSET position or RANG values that have been saved in J-type variables can be read as the CALSET position.

Pressing [F1 Read CALSET Pos] will display the following window.

Select the target item to read, and then press [OK] to acquire the CALSET position.

Also, the CALSET position that has been edited directly from the Recover CALSET data window can be saved in J-type variables by pressing [F2 Save CALSET Pos].

Keys other than function keys
Restriction If "OFF" is selected, any axis where CALSET is not required can be selected as well.
Available function keys
[F1 Read CALSET Pos] Read J-type variables or RANG values as a CALSET position.
[F2 Save CALSET Pos] Save the CALSET position which is currently displayed in J-type variables.
[F3 Break] Display the brake setting.
[F4 Cancel All] Change all joints to "No CALSET (OFF)".
[F5 Edit] Display the value editor.
[F6 Select All]

Change all joints to "CALSET (ON)".

Change it ON, and press [OK] to restore CALSET data.

Ver.2.7.* or Lower

To individually select ON/OFF for each joint, directly touch ON/OFF characters of each joint to set.

Keys other than function keys
Restriction
(Ver.1.12.* or higher.)
If "OFF" is selected, any axis where CALSET is not required can be selected as well.
Available function keys
[F4 Cancel All] Change all joints to "No CALSET (OFF)".
[F6 Select All]

Change all joints to "CALSET (ON)".

Change it ON, and press [OK] to restore CALSET data.

ID : 1756