<< Prev        Next >>

ID : 5490

TrackStartArea

Function

Configures the tracking range.

This command is available in Ver.1.6.* or higher.

Syntax

TrackStartArea Conveyor number, The upstream limit of the tracking range,
The downstream limit of the tracking range

Guaranteed Entry

Conveyor number

Specifies the conveyor number (1-16) to be used by integer type data.
(If your robot controller is Ver.1.11.* or lower, available conveyor number is 1 or 2.)

The upstream limit of the tracking range

Specifies by integer type data.

The downstream limit of the tracking range

Specifies by integer type data.

Description

Set the upstream limit of the tracking range and downstream limit of the tracking range.
When setting the tracking range, you need to take the conveyor speed and the maximum reach of the robot arm into consideration.

Attention

This command is dedicated for conveyor and circular tracking.

Example

Set the value of the upstream limit of the tracking range at 500mm and the value of the downstream limit of the tracking range at 800mm.

TrackStartArea 1, 500, 800